Show chassis cluster information

From Juniper Clue

Jump to: navigation, search

On SRX series firewalls in a cluster setup, this shows detailed information about the current cluster status and past events.

Examples

user@srx-node0> show chassis cluster information
node0:
--------------------------------------------------------------------------
Control link statistics:
    Control link 0:
        Heartbeat packets sent: 206369
        Heartbeat packets received: 206367
        Heartbeat packet errors: 0
        Duplicate heartbeat packets received: 0
    Control recovery packet count: 0
    Sequence number of last heartbeat packet sent: 206367
    Sequence number of last heartbeat packet received: 430097
Fabric link statistics:
    Probes sent: 206367
    Probes received: 206328
    Probe errors: 0
    Probes not processed: 22547
    Probes dropped due to control link down: 0
    Sequence number of last probe sent: 206367
    Sequence number of last probe received: 430097
Chassis cluster LED information:
    Current LED color: Green
    Last LED change reason: No failures
Control port tagging:
    Enabled

Cold Synchronization:
    Status:
        Cold synchronization completed for: flowd
        Cold synchronization failed for: N/A
        Cold synchronization not known for: N/A
        Current Monitoring Weight: 0

    Statistics:
        Number of cold synchronization completed: 1
        Number of cold synchronization failed: 0

            PFE             Cold-Sync complete           Cold-Sync failed
            ----------------------------------------------------------------
         flowd                   1                             0

    Events:
        Dec 14 18:10:12.861 : Cold sync completed for PFE flowd

Redundancy group: 0, Threshold: 255, Monitoring failures: none
    Events:
        Dec 14 18:09:15.720 : hold->secondary, reason: Hold timer expired

Redundancy group: 1, Threshold: 255, Monitoring failures: none
    Events:
        Dec 14 18:09:15.726 : hold->secondary, reason: Hold timer expired

Interface monitoring:
    Statistics:
        Monitored interface failure count: 0

    Events:
        Dec 14 18:09:22.949 : Interface ge-5/0/9 monitored by rg 1, changed state from Down to Up
        Dec 14 18:09:23.442 : Interface ge-5/0/11 monitored by rg 1, changed state from Down to Up
        Dec 14 18:09:23.909 : Interface ge-5/0/4 monitored by rg 1, changed state from Down to Up
        Dec 14 18:10:06.933 : Interface ge-0/0/4 monitored by rg 1, changed state from Down to Up
        Dec 14 18:10:07.002 : Interface ge-0/0/8 monitored by rg 1, changed state from Down to Up
        Dec 14 18:10:07.185 : Interface ge-0/0/10 monitored by rg 1, changed state from Down to Up

Fabric monitoring:
    Status:
        State: Disabled
        Activation status: Active

node1:
--------------------------------------------------------------------------
Control link statistics:
    Control link 0:
        Heartbeat packets sent: 430099
        Heartbeat packets received: 429970
        Heartbeat packet errors: 0
        Duplicate heartbeat packets received: 0
    Control recovery packet count: 0
    Sequence number of last heartbeat packet sent: 430097
    Sequence number of last heartbeat packet received: 206367
Fabric link statistics:
    Probes sent: 430097
    Probes received: 429890
    Probe errors: 0
    Probes not processed: 41151
    Probes dropped due to control link down: 0
    Sequence number of last probe sent: 430097
    Sequence number of last probe received: 206367
Chassis cluster LED information:
    Current LED color: Green
    Last LED change reason: No failures
Control port tagging:
    Enabled

Cold Synchronization:
    Status:
        Cold synchronization completed for: flowd
        Cold synchronization failed for: N/A
        Cold synchronization not known for: N/A
        Current Monitoring Weight: 0

    Statistics:
        Number of cold synchronization completed: 1
        Number of cold synchronization failed: 0

            PFE             Cold-Sync complete           Cold-Sync failed
            ----------------------------------------------------------------
         flowd                   1                             0

    Events:
        Dec  9 12:28:37.551 : Cold sync completed for PFE flowd

Redundancy group: 0, Threshold: 255, Monitoring failures: none
    Events:
        Dec  9 12:27:37.349 : hold->secondary, reason: Hold timer expired
        Dec 14 18:04:30.980 : secondary->primary, reason: Device timer expired

Redundancy group: 1, Threshold: 255, Monitoring failures: none
    Events:
        Dec  9 12:27:37.354 : hold->secondary, reason: Hold timer expired
        Dec 14 18:04:31.008 : secondary->primary, reason: Device timer expired

Interface monitoring:
    Statistics:
        Monitored interface failure count: 3

    Events:
        Dec  9 12:27:47.741 : Interface ge-0/0/4 monitored by rg 1, changed state from Down to Up
        Dec  9 12:28:31.677 : Interface ge-5/0/4 monitored by rg 1, changed state from Down to Up
        Dec  9 12:28:31.842 : Interface ge-5/0/9 monitored by rg 1, changed state from Down to Up
        Dec  9 12:28:32.256 : Interface ge-5/0/11 monitored by rg 1, changed state from Down to Up
        Dec 14 18:06:28.296 : Interface ge-0/0/4 monitored by rg 1, changed state from Up to Down
        Dec 14 18:06:28.383 : Interface ge-0/0/8 monitored by rg 1, changed state from Up to Down
        Dec 14 18:06:28.472 : Interface ge-0/0/10 monitored by rg 1, changed state from Up to Down
        Dec 14 18:10:07.506 : Interface ge-0/0/4 monitored by rg 1, changed state from Down to Up
        Dec 14 18:10:07.550 : Interface ge-0/0/8 monitored by rg 1, changed state from Down to Up
        Dec 14 18:10:07.551 : Interface ge-0/0/10 monitored by rg 1, changed state from Down to Up

Fabric monitoring:
    Status:
        State: Disabled
        Activation status: Active